CABLE COATING 3iAPPROVED BY FACTORY MUTUAL | |
|
Cable Coating 3i is a heavy-bodied, water-based intumescent coating which is designed to prevent flame spread along the jacketing of electrical (or other) cables and to provide a thermal barrier for protection against heat damage. CC3i will also prevent a short circuit within an electrical cable from starting a fire and will help identify the location of such a short circuit by forming an intumescent char at the spot. CC3i can be applied to grouped cables or single cables. Cable Coating 3i is a unique acrylic latex emulsion which has excellent resistance to weathering and aging and which remains flexible indefinitely allowing for cable movement and removal. It is suitable for indoor or outdoor application. Cable Coating 3i is approved by Factory Mutual at our recommended dried film thickness of 1/16th inch and it does not require cable derating (see complete Factory Mutual Test Report). Cable Coating 3i forms a protective intumescent char when exposed to flame or to a temperature above 350ºF. This char should be removed completely and clean cables should be recoated if intumescence should occur. Cable Coating 3i is easily applied by brush or spray and it adheres well to cables, allowing for vertical or overhead application. Care should be taken to see that cables are clean and dry before application, particularly that they are free of oil, grease and grit. Cable Coating 3i should be applied in 2 coats to ensure complete coverage. NOTE: CABLE COATING 3i MUST BE PROTECTED FROM FREEZING DURING STORAGE. During application it must be protected from freezing, moisture, oil, grease, and foot traffic until it is thoroughly cured. |
COLOR Yellow, Gray, Black, White (Special colors available upon request) COVERAGE (ASTM C 461) 14 sq. ft./gal. @ 1/16" dry (.34 mē/liter @ 1.59 mm) Actual flat surface coverage. Note: Because of the irregular surfaces, a nominal square foot of cable tray, when loaded with cables, will present more than a square foot of surface area to be coated. DRYING TIME (ASTM D 1640) To touch: 2 hours Through: 24 to 48 hours (Dependent upon substrate temperature, ambient temperature and relative humidity) WEIGHT PER U.S. GALLON (ASTM D 1475) 9.9 pounds (1.19 kg) SOLIDS 62% by weight 53% + 2% by volume APPLICATION TEMPERATURE RANGE 40ºF (4ºC) to 110ºF (43ºC) FLAMMABILITY Passess IEEE-383 flame propagation test (full test report available upon request) Will not support combustion in wet or dry state. FLAME SPREAD INDEX ASTM E 84: 15 ASTM E 162: 16 @ 1/16" dry film (1.59 mm) INTUMESCENCE 600% to 700% typical after 10 minute exposure to 1600ºF RADIOACTIVITY DECONTAMINATION FACTOR (ASTM D 4256-83 and ANSI 5.12-1974) 5.83 after 10 weeks curing time CLEANUP Wet state - water Dry state - safety solvent RECOMMENDED SHELF LIFE 12 months in unopened container @40ºF (4ºC) to 90ºF (32ºC) CAUTION The addition of water or any thinning agent to this product will change its physical properties and will adversely affect its performance. No expressed or implied warranty will be offered on applications where this product has been thinned or altered in any manner. |